Technical specifications

General technical specifications

Electrical data

Line connection voltage

(up to 2000 m (6562 ft) above sea level)

200 V ... 240 V 1 AC ±10 %
(-15 % < 1 min) or

380 ... 480 V 3 AC ±10 %
(-15 % < 1 min)

Line frequency

47 … 63 Hz

Line power factor

with rated power

 

 

  • Fundamental power factor (cos ϕ1)

> 0.96

  • Total (λ)
 

 

  • 200 … 240 V 1 AC

0.45 … 0.7

  • 380 … 480 V 3 AC

0.65 … 0.95

Overvoltage category

to EN 60664-1

Class III

Precharging frequency

of the DC link, max.

1× every 30 s

DC link voltage, approx.

1.35 x line voltage

Output frequency

 

 

  • Control type Servo

0 … 650 Hz 1)

  • Control type Vector

0 … 300 Hz 1)

  • Control type V/f

0 … 600 Hz 1)

Electronics power supply

24 V DC -15 %/+20 %

Radio interference suppression

  • Standard

No radio interference suppression

  • With integrated line filter

Category C2 to EN 61800‑3

Ambient conditions

Cooling method

Forced air cooling through a built-in fan

Permissible ambient or coolant temperature (air)

in operation for line-side components, Power Modules

0 … 40 °C (32  … 104 °F) without derating,
> 40 … 55 °C (104  … 131 °F) see derating characteristics

Site altitude

Up to 1000 m (3281 ft) above sea level without derating,
> 1000 ... 4000 m (3281 ... 13124 ft) above sea level see derating characteristics

Conformity

CE (low-voltage and EMC Directives)

Approvals

cULus

  • 200 … 240 V 1 AC
 

 

  • Frame size FSA

File No. E192450

  • 380 … 480 V 3 AC
 

 

  • Frame sizes FSA … FSC

File No. E121068

  • Frame sizes FSD … FSF

File No. E192450

Safety Integrated

Safety Integrity Level 2 (SIL 2) to IEC 61508,
control category 3 to EN 954-1
(for further information, see the Safety Integrated section)


1) Note correlation between max. output frequency, pulse frequency and current derating, see System description.

 

Line voltage 200 ... 240 V 1 AC

PM340 Power Modules in blocksize format

 

 

 

 

6SL3210-1SB11‑0...

6SL3210-1SB12‑3...

6SL3210-1SB14‑0...

Output current

 

 

 

 

 

 

 

 

  • Rated current Irated

A

0.9

2.3

3.9

  • Base-load current IH

A

0.8

2.0

3.4

  • For S6 duty (40 %) IS6

A

1.4

3.3

5.5

  • I max

A

2.0

4.6

7.8

Type rating 3)

based on Irated

kW (HP)

0.12 (0.2)

0.37 (0.5)

0.75 (0.75)

Rated pulse frequency

kHz

4

4

4

Power loss

kW

0.06

0.075

0.11

Cooling air requirement

m3/s (ft3/s)

0.005 (0.02)

0.005 (0.02)

0.005 (0.02)

Sound pressure levelLpA (1 m)

dB

< 45

< 45

< 45

24 V DC power supply

for the Control Unit

A

1.0

1.0

1.0

Rated input current1)

with/without line reactor

A

1.4/2.2

4/6

6.5/10

Resistance value

of the external braking resistor

Ω 

≥ 180

≥ 180

≥ 180

Cable length

to braking resistor, max.

m (ft)

15 (49)

15 (49)

15 (49)

Line connection

L, N

 

 

Screw-type terminals

Screw-type terminals

Screw-type terminals

  • Conductor cross-section

mm2

1.0 … 2.5

1.0 … 2.5

1.0 … 2.5

Motor connection

U2, V2, W2

 

 

Screw-type terminals

Screw-type terminals

Screw-type terminals

  • Conductor cross-section

mm2

1.0 … 2.5

1.0 … 2.5

1.0 … 2.5

DC link connection, 
connection for the braking resistor

DCP/R1, DCN, R2

 

 

Screw-type terminals

Screw-type terminals

Screw-type terminals

  • Conductor cross-section

mm2

1.0 … 2.5

1.0 … 2.5

1.0 … 2.5

PE connection

 

 

M4 screw

M4 screw

M4 screw

Motor cable length2), max.

(without external options)

 

 

 

 

 

 

 

 

  • Shielded

m (ft)

50 (164)

50 (164)

50 (164)

  • Unshielded

m (ft)

75 (246)

75 (246)

75 (246)

Degree of protection

 

 

IP20

IP20

IP20

Dimensions

 

 

 

 

 

 

 

 

  • Width

mm (in)

73 (2.87)

73 (2.87)

73 (2.87)

  • Height

mm (in)

173 (6.81)

173 (6.81)

173 (6.81)

  • Depth
 

 

 

 

 

 

 

 

  • PM340

mm (in)

145 (5.71)

145 (5.71)

145 (5.71)

  • PM340 with CU310

mm (in)

234.6 (9.24)

234.6 (9.24)

234.6 (9.24)

  • PM340 with CUA31/CUA32

mm (in)

175.3 (6.90)

175.3 (6.90)

175.3 (6.90)

Frame size

 

 

FSA

FSA

FSA

Weight, approx.

kg (lb)

1.2 (3)

1.3 (3)

1.3 (3)


1) The input current depends on the motor load and line impedance. The input currents apply for rated power loading (based on Irated) for a line impedance corresponding to uk = 1 %.

2) Max. motor cable length 15 m (49 ft) (shielded) for PM340 Power Modules with integrated line filter to maintain the limit values of EN 61800-3 Category C2.

3) Nominal HP based on asynchronous motors (induction motors). For specific sizing select drive based on motor nameplate current and overload.

 

Line voltage 380 ... 480 V 3 AC

PM340 Power Modules in blocksize format

 

 

 

 

6SL3210-1SE11‑3UA0

6SL3210-1SE11‑7UA0

6SL3210-1SE12‑2UA0

6SL3210-1SE13‑1UA0

6SL3210-1SE14‑1UA0

Output current

 

 

 

 

 

 

 

 

 

 

 

 

  • Rated current Irated

A

1.3

1.7

2.2

3.1

4.1

  • Base-load current IH

A

1.1

1.5

1.9

2.7

3.6

  • For S6 duty (40 %) IS6

A

1.3

2.0

2.5

3.5

4.5

  • I max

A

2.6

3.4

4.4

6.2

8.2

Type rating 1)

 

 

 

 

 

 

 

 

 

 

 

 

  • Based onIrated

kW (HP)

0.37 (0.5)

0.55 (0.75)

0.75 (1)

1.1 (1.5)

1.5 (2)

  • Based on IH

kW (HP)

0.37 (0.5)

0.55 (0.5)

0.75 (0.75)

1.1 (1)

1.5 (2)

Rated pulse frequency

kHz

4

4

4

4

4

Power loss

kW

0.10

0.10

0.10

0.11

0.11

Cooling air requirement

m3/s (ft3/s)

0.005 (0.2)

0.005 (0.2)

0.005 (0.2)

0.005 (0.2)

0.005 (0.2)

Sound pressure levelLpA (1 m)

dB

< 45

< 45

< 45

< 45

< 45

24 V DC power supply

for the Control Unit

A

1.0

1.0

1.0

1.0

1.0

Rated input current2)

with/without line reactor

A

1.3/1.7

1.7/2.2

2.2/2.6

3.1/3.9

4.1/4.8

Resistance value

of the external braking resistor

Ω 

≥ 390

≥ 390

≥ 390

≥ 390

≥ 390

Cable length

to braking resistor, max.

m (ft)

15 (49)

15 (49)

15 (49)

15 (49)

15 (49)

Line connection

L1, L2, L3

 

 

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

  • Conductor cross-section

mm2

1.0 … 2.5

1.0 … 2.5

1.0 … 2.5

1.0 … 2.5

1.0 … 2.5

Motor connection

U2, V2, W2

 

 

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

  • Conductor cross-section

mm2

1.0 … 2.5

1.0 … 2.5

1.0 … 2.5

1.0 … 2.5

1.0 … 2.5

DC link connection, 
connection for braking resistor

DCP/R1, DCN, R2

 

 

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

  • Conductor cross-section

mm2

1.0 … 2.5

1.0 … 2.5

1.0 … 2.5

1.0 … 2.5

1.0 … 2.5

PE connection

 

 

M4 screw

M4 screw

M4 screw

M4 screw

M4 screw

Motor cable length 3), max.

 

 

 

 

 

 

 

 

 

 

 

 

  • Shielded

m (ft)

50 (164)

50 (164)

50 (164)

50 (164)

50 (164)

  • Unshielded

m (ft)

75 (246)

75 (246)

75 (246)

75 (246)

75 (246)

Degree of protection

 

 

IP20

IP20

IP20

IP20

IP20

Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

  • Width

mm (in)

73 (2.87)

73 (2.87)

73 (2.87)

73 (2.87)

73 (2.87)

  • Height

mm (in)

173 (6.81)

173 (6.81)

173 (6.81)

173 (6.81)

173 (6.81)

  • Depth
 

 

 

 

 

 

 

 

 

 

 

 

  • PM340

mm (in)

145 (5.71)

145 (5.71)

145 (5.71)

145 (5.71)

145 (5.71)

  • PM340 with CU310

mm (in)

234.6 (9.24)

234.6 (9.24)

234.6 (9.24)

234.6 (9.24)

234.6 (9.24)

  • PM340 with CUA31/CUA32

mm (in)

175.3 (6.90)

175.3 (6.90)

175.3 (6.90)

175.3 (6.90)

175.3 (6.90)

Frame size

 

 

FSA

FSA

FSA

FSA

FSA

Weight, approx.

kg (lb)

1.2 (3)

1.2 (3)

1.2 (3)

1.2 (3)

1.2 (3)


1) Nominal HP based on asynchronous motors (induction motors) and 460 V AC. For specific sizing select drive based on motor nameplate current and overload.

2) The input current depends on the motor load and line impedance. The input currents apply for rated power loading (based on Irated) for a line impedance corresponding to uk = 1 %.

3) Max. motor cable length 25 m (82 ft) (shielded) for PM340 Power Modules with integrated line filter to maintain the limit values of EN 61800-3 Category C2.

 

Line voltage 380 ... 480 V 3 AC

PM340 Power Modules in blocksize format

 

 

 

 

6SL3210-1SE16-0...

6SL3210-1SE17-7...

6SL3210-1SE21‑0...

6SL3210-1SE21-8...

6SL3210-1SE22-5...

6SL3210-1SE23‑2...

Output current

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  • Rated current Irated

A

5.9

7.7

10.2

18

25

32

  • Base-load current IH

A

5.2

6.8

9.1

14

21

27

  • For S6 duty (40 %) IS6

A

6.4

8.3

10.8

19.6

27.8

37.1

  • I max

A

11.8

15.4

20.4

26.4

38

52

Type rating 1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  • Based onIrated

kW (HP)

2.2 (3)

3 (5)

4 (5)

7.5 (10)

11 (15)

15 (20)

  • Based on IH

kW (HP)

2.2 (3)

3 (4)

4 (5)

5.5 (10)

7.5 (15)

11 (20)

Rated pulse frequency

kHz

4

4

4

4

4

4

Power loss

kW

0.14

0.16

0.18

0.24

0.30

0.40

Cooling air requirement

m3/s (ft3/s)

0.009 (0.3)

0.009 (0.3)

0.009 (0.3)

0.038 (1.3)

0.038 (1.3)

0.038 (1.3)

Sound pressure levelLpA (1 m)

dB

< 50

< 50

< 50

< 60

< 60

< 60

24 V DC power supply

for the Control Unit

A

1.0

1.0

1.0

1.0

1.0

1.0

Rated input current2)

with/without line reactor

A

5.6/6.7

7.5/8.9

9.8/12.4

17.1/23.1

24.6/32.6

33/39

Resistance value

of the external braking resistor

Ω 

≥ 160

≥ 160

≥ 160

≥ 56

≥ 56

≥ 56

Cable length

to braking resistor, max.

m (ft)

15 (49)

15 (49)

15 (49)

15 (49)

15 (49)

15 (49)

Line connection

L1, L2, L3

 

 

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

  • Conductor cross-section

mm2

1.0 … 6

1.0 … 6

1.0 … 6

2.5 … 10

2.5 … 10

2.5 … 10

Motor connection

U2, V2, W2

 

 

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

  • Conductor cross-section

mm2

1.0 … 6

1.0 … 6

1.0 … 6

2.5 … 10

2.5 … 10

2.5 … 10

DC link connection, 
connection for braking resistor

DCP/R1, DCN, R2

 

 

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

Screw-type terminals

  • Conductor cross-section

mm2

1.0 … 6

1.0 … 6

1.0 … 6

2.5 … 10 10

2.5 … 10 10

2.5 … 10 10

PE connection

 

 

M5 screw

M5 screw

M5 screw

M5 screw

M5 screw

M5 screw

Motor cable length3), max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  • Shielded

m (ft)

50 (164)

50 (164)

50 (164)

50 (164)

50 (164)

50 (164)

  • Unshielded

m (ft)

75 (246)

75 (246)

75 (246)

75 (246)

75 (246)

75 (246)

Degree of protection

 

 

IP20

IP20

IP20

IP20

IP20

IP20

Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  • Width

mm (in)

153 (6.02)

153 (6.02)

153 (6.02)

188.4 (7.42)

188.4 (7.42)

188.4 (7.42)

  • Height

mm (in)

270 (10.63)

270 (10.63)

270 (10.63)

333.4 (13.13)

333.4 (13.13)

333.4 (13.13)

  • Depth
 

 

 

 

 

 

 

 

 

 

 

 

 

 

  • PM340

mm (in)

165 (6.50)

165 (6.50)

165 (6.50)

185 (7.28)

185 (7.28)

185 (7.28)

  • PM340 with CU310

mm (in)

254.6 (10.02)

254.6 (10.02)

254.6 (10.02)

274.6 (10.81)

274.6 (10.81)

274.6 (10.81)

  • PM340 with CUA31/CUA32

mm (in)

195.3 (7.69)

195.3 (7.69)

195.3 (7.69)

215.3 (8.48)

215.3 (8.48)

215.3 (8.48)

Frame size

 

 

FSB

FSB

FSB

FSC

FSC

FSC

Weight, approx.

kg (lb)

4.0 (9)

4.0 (9)

4.0 (9)

6.5 (14)

6.5 (14)

6.5 (14)

 

Etiketleri ayırmak için boşluk kullanınız. Deyim tipindeki etiketler için tekli tırnak (') kullanınız.

Ürün Yorumları

Kendi Yorumunuzu Yazın

Yorumladığınız ürün : SIEMENS SINAMICS POWER MODULE 340 (6SL3210-1SE12-2UA0)

Bu ürüne kaç puan verirsiniz ? *

  1 yıldız 2 yıldız 3 yıldız 4 yıldız 5 yıldız
Kalite
Fiyat